EJA110E differential pressure transmitter with single crystal silicon resonant sensor suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. Standard accuracy is 0.055% and 0.04% accuracy can be reached with optional suffix code /HAC. Minimum measure range is range F with 0 to 5Kpa and range L with 0 to 10Kpa, which owns high performance capability for low flow, low level measurement; maximum measure range is 0 to 140bar which is also capable for some special high pressure work conditions such as oil & gas, refinery, power plant and nuclear plants. For static pressure, standard type is 160bar, but high pressure 250bar is also available with code /HG, High pressure-proof structure. Burst Pressure Limits is 69MPa (10,000 psi) for wetted parts material S, except for Measurement span F; 47MPa (6,800 psi) for wetted parts material other than S or Measurement span F.
Tantalum and monel capsule are also available for high corrosion working cases, in this case can also selected according cover flanges and process connectors, vend and drain plugs. For bolting material, B7 carbon steel, 316L SST or 660 SST selectable, for Cover O-rings, Buna-N and fluoro-rubber is optional; for Name plate and tag, it's standard based on 316 SST, liquid filling is Silicone, and fluorinated oil is optional.
EJA-E series models issued in 2016 for replacement of predecessor EJA-A series due to new regulations and approvals, and all EJA-E series are certified as complying with SIL 2 for safety requirement.
Measurement |
kPa |
in H2O |
mbar |
mmH2O |
mmH2O |
|
F |
Span |
0.5 to 5 |
2.0 to 20 |
5 to 50 |
50 to 500 |
50 to 500 |
Range |
-5 to 5 |
-20 to 20 |
-50 to 50 |
-500 to 500 |
-500 to 500 |
|
L |
Span |
0.5 to 10 |
2.0 to 40 |
5 to 100 |
50 to 1000 |
50 to 1000 |
Range |
-10 to 10 |
-40 to 40 |
-100 to 100 |
-1000 to 1000 |
-1000 to 1000 |
|
M |
Span |
1 to 100 |
4 to 400 |
10 to 1000 |
100 to 10000 |
100 to 10000 |
Range |
-100 to 100 |
-400 to 400 |
-1000 to 1000 |
-10000 to 10000 |
-10000 to 10000 |
|
H |
Span |
5 to 500 |
20 to 2000 |
50 to 5000 |
0.05 to 5kgf/cm2 |
0.05 to 5kgf/cm2 |
Range |
-500 to 500 |
-2000 to 2000 |
-5000 to 5000 |
-5 to 5kgf/cm2 |
-5 to 5kgf/cm2 |
|
V |
Span |
0.14 to 14Mpa |
20 to 2000psi |
1.4 to 140bar |
1.4 to 140kgf/cm2 |
1.4 to 140kgf/cm2 |
Range |
-0.5 to 14Mpa |
-71 to 2000psi |
-5 to 140bar |
-5 to 140kgf/cm2 |
-5 to 140kgf/cm |
3. Wetted Parts Materials
Wetted |
Cover flange and process connector |
Capsule |
Capsule gasket |
Vent/Drain plug |
S |
ASTM CF-8M |
Hastelloy C-276 (Diaphragm) F316L SST, 316L SST (Others) |
Teflon-coated 316L SST |
316 SST |
H |
ASTM CF-8M |
Hastelloy C-276 |
PTFE Teflon |
316 SST |
M |
ASTM CF-8M |
Monel |
PTFE Teflon |
317 SST |
T |
ASTM CF-8M |
Tantalum |
PTFE Teflon |
318 SST |
A |
Hastelloy C-276 |
Hastelloy C-276 |
PTFE Teflon |
Hastelloy C-276 |
D |
Hastelloy C-276 |
Tantalum |
PTFE Teflon |
Hastelloy C-276 |
B |
Monel equivalent |
Monel |
PTFE Teflon |
Monel |
4. Model and suffix codes of transmitter
Main Code |
Suffix Codes |
Description |
|||||||||
EJA110E |
Differential pressure transmitter |
||||||||||
Output signal |
-D |
4 to 20 mA DC with digital communication (BRAIN protocol) |
|||||||||
-J |
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol) |
||||||||||
-F |
Digital communication (FOUNDATION Fieldbus protocol) |
||||||||||
-G |
Digital communication (PROFIBUS PA protocol) |
||||||||||
-Q |
Low Power, 1 to 5 V DC with digital communication (HART 7 protocol) |
||||||||||
Measurement span (capsule) |
F |
0.5 to 5kPa (2.0 to 20 inH2O) |
|||||||||
L |
0.5 to 10kPa (2.0 to 40 inH2O) |
||||||||||
M |
1 to 100kPa (4 to 400 inH2O) |
||||||||||
H |
5 to 500kPa (20 to 2000 inH2O) |
||||||||||
V |
0.14 to 14MPa (20 to 2000 psi) |
||||||||||
Wetted parts material |
Refer to “Wetted Parts Material” Table |
||||||||||
Process connections |
0 |
without process connector(Rc1/4 female on the cover flanges) |
|||||||||
1 |
with Rc1/4 female process connector |
||||||||||
2 |
with Rc1/2 female process connector |
||||||||||
3 |
with 1/4 NPT female process connector |
||||||||||
4 |
with 1/2 NPT female process connector |
||||||||||
5 |
without process connector (1/4 NPT female on the cover flanges) |
||||||||||
Bolts and nuts material |
J |
B7 carbon steel |
|||||||||
G |
316L SST |
||||||||||
C |
660 SST |
||||||||||
Installation |
-7 |
Vertical piping, left side high pressure, and process connection downside |
|||||||||
-8 |
Horizontal piping and right side high pressure |
||||||||||
-9 |
Horizontal piping and left side high pressure |
||||||||||
-B |
Bottom Process Connection, left side high pressure |
||||||||||
-U |
Universal flange |
||||||||||
Amplifier housing |
1 |
Cast aluminum alloy |
|||||||||
3 |
Cast aluminum alloy with corrosion resistance properties |
||||||||||
2 |
ASTM CF-8M stainless steel |
||||||||||
Electrical connection |
0 |
G1/2 female, one electrical connection without blind plugs |
|||||||||
2 |
1/2 NPT female, two electrical connections without blind plugs |
||||||||||
4 |
M20 female, two electrical connections without blind plugs |
||||||||||
5 |
G1/2 female, two electrical connections and a blind plug |
||||||||||
7 |
1/2 NPT female, two electrical connections and a blind plug |
||||||||||
9 |
M20 female, two electrical connections and a blind plug |
||||||||||
A |
G1/2 female, two electrical connections and a SUS316 blind plug |
||||||||||
C |
1/2 NPT female, two electrical connections and a SUS316 blind plug |
||||||||||
D |
M20 female, two electrical connections and a SUS316 blind plug |
||||||||||
Integral indicator |
D |
Digital indicator |
|||||||||
E |
Digital indicator with the range setting switch (push button) |
||||||||||
N |
None |
||||||||||
Mounting bracket |
B |
304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
|||||||||
D |
304 SST 2-inch pipe mounting, L type (for vertical piping) |
||||||||||
J |
316 SST 2-inch pipe mounting, flat type (for horizontal piping) |
||||||||||
K |
316 SST 2-inch pipe mounting, L type (for vertical piping) |
||||||||||
M |
316 SST 2-inch pipe mounting (for bottom process connection type) |
||||||||||
N |
None |
||||||||||
Optional codes |
/Optional codes |
5. Model and suffix codes of 3 way and 5 way manifold
Model |
Suffix Codes |
Description |
|||||||
CV |
Main code |
||||||||
Type |
3 |
3 way manifold |
|||||||
5 |
5 way manifold |
||||||||
Structure |
P |
Conventional flat structure |
|||||||
T |
Conventional Traditional structure |
||||||||
H |
H structure(only for process connection W) |
||||||||
Universal |
-0 |
Always 0 |
|||||||
Process connection |
N |
1/2NPTF |
|||||||
R |
Rc1/2(F) |
||||||||
W |
Flange(only for H structure type) |
||||||||
Wetted part material |
E |
SUS304 |
|||||||
F |
SUS316 |
||||||||
D |
SUS316L |
||||||||
G |
SUS316H |
||||||||
J |
SUS321 |
||||||||
M |
Monel |
||||||||
H |
Hastelloy C-276 |
||||||||
Max. work pressure |
3 |
32Mpa |
|||||||
4 |
42Mpa |
||||||||
Service temperature |
L |
-40 to 150℃ |
|||||||
Mounting bolt |
E |
7/16-20UNF inch standard |
|||||||
Optional codes |
/Optional codes |
||||||||
Connector style |
K1 |
LOK connector Φ14 |
|||||||
K3 |
LOK connector Φ16 |
||||||||
D1 |
Pad connector Φ14*2 |
||||||||
D2 |
Pad connector Φ14*3 |
||||||||
D3 |
Pad connector Φ16*3 |
||||||||
Degrease |
T |
Degrease cleaning |
|||||||
Vent plug |
P |
1/4NPT vent plug |
6. Mounting & Dimensions