DC VOLTAGE

12V

RATED CURRENT

5A

 

IP67 type waterproof switching power supply 60Watt

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-25 13:40
Browse the number: 194
inquiry
Company Profile
 
 
Product details


 

MODEL

LPV-60-12

OUTPUT


DC VOLTAGE


12V


RATED CURRENT


5A


CURRENT RANGE


0~12A


RATED POWER


60W


RIPPLE & NOISE(max).Note.2


120mVp-p


VOLTAGE ADJ.RANGE


~


VOLTAGE TOLERANCE Note.3


±1.0%


LINE REGULATION   Note.4


±0.5%


LOAD REGULATION  Note.5


±0.5%


SETUP,RISE TIME


500ms,20ms/230VAC   500ms,20ms/115VAC at full load


HOLD UP TIME(Typ.)


30ms/230VAC  25ms/115VAC at full load

INPUT


VOLTAGE RANGE


85~364VAC OR 248~373VDC


FREQUENCY RANGE


47~63HZ


EFFICIENCY(Typ.)


86%


AC CURRENT(Typ.)


2A/115VAC  1.2A/230VAC


INRUSH CURRENT(Typ.)


COLD START 36A


LEAKAGE CURENT


<2mA/240VAC

PROTECTION


OVERLOAD


110~150% rated output power


Protection type: C an be con tinued, recovers automatically after fault condition is removed


OVER VOLTAGE


~


Protection type : Shut down, recovers automatically after temperature goes down

ENVIRONMENT


WORKING TEMP.


-20~+60°C  (Refer to "Derating Curve")


WORKING HUMIDITY


20~90% RH non-condensing


STORAGE TEMP HUMIDITY


-40~+85°C 10~95%RH


TEMPCOEFFICIENT


±0.03% /°C(0~50 °C )


VIBRATION


10~500HZ,2G10min/1cycle,60min.each alongX,Y,Zaxes

SAFETY & EMC(Note 7)      


SAFETY  STANDARDS


UL60950-1, CB(IE60950-1),CCC GB4943.1:2011 approved


WITHSTAND VOLTAGE


l/P-o/P:3KVAC; l/P-FG:2KVAC; O/P-FG:0.5KVAC


ISOLATIONRESISTANCE


I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC / 25°C/ 70% RH


EMC EMISSION


Compliance to EN55015, FCC part 15 class B


EMC IMMUNITY


Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A

OTHERS   


MTBF


320.7Khrs min MIL-HDBK-217F(25°C)


DIMENSION


159*98*38mm(L*W*H)


PACKING


0.55Kg; 30pcs/17.5Kg/0.97CUFT

NOTE


1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C  of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.Tolerance : includes set up tolerance, line regulation and load regulation.

4.Constant current operation region is within 60% ~100% rated output voltage, and the output power must be more than 60% rated output power.This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

5.Derating may be needed under low input voltages. Please check the static characteristics for more details.

6.Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.

7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.


 